VERITAS Volume Manager 4.1 Troubleshooting Guide

Error Messages
Understanding Messages
Chapter 6108
c8t0d1 /0/4/0/0.8.0.108.0.0.1
c8t0d2 /0/4/0/0.8.0.108.0.0.2
controllers
#
product
#
pathgroups
Case 2: Some arrays such as EMC and HDS provide mirroring in hardware. When a
LUN pair is split, depending on how the process is performed, this may result in two
disks with the same disk ID.
Check with your array vendor to make sure that you are using the correct split
procedure. If you know which LUNs you want to use, choose which path to exclude,
and then either edit the file /etc/vx/vxvm.exclude, or, if vxconfigd is running, select
item 1 (Suppress all paths through a controller from VxVM’s view) or item 2
(Suppress a path from VxVM’s view) from vxdiskadm option 17 (Prevent
multipathing/Suppress devices from VxVM’s view).
Case 3: If disks have become duplicated using the dd command or any other disk
copying utility, choose which set of duplicate disks you want to exclude, and then
either edit the file /etc/vx/vxvm.exclude, or, if vxconfigd is running, select item 1
(Suppress all paths through a controller from VxVM’s view) or item 2 (Suppress a
path from VxVM’s view) from vxdiskadm option 17 (Prevent multipathing/Suppress
devices from VxVM’s view).