VERITAS Volume Manager 4.1 Troubleshooting Guide

Error Messages
Understanding Messages
Chapter 6106
Action: If a connection to SAL is desired, ensure that the correct version of SAL is
installed and configured correctly. Otherwise, suppress communication between vxassist
and SAL by adding the following line to the vxassist defaults file (usually
/etc/default/vxassist):
salcontact=no
V-5-1-4625
VxVM vxassist WARNING V-5-1-4625 SAL authentication failed...
Description: The SAN Access Layer (SAL) rejects the credentials that are supplied by the
vxassist command.
Action: If connection to SAL is desired, use the vxspcshow command to set a valid user
name and password. Otherwise, suppress communication between vxassist and SAL by
adding the following line to the vxassist defaults file (usually /etc/default/vxassist):
salcontact=no
V-5-1-5150
VxVM vxassist ERROR V-5-1-5150 Insufficient number of active snapshot
mirrors in snapshot_volume.
Description: An attempt to snap back a specified number of snapshot mirrors to their
original volume failed.
Action: Specify a number of snapshot mirrors less than or equal to the number in the
snapshot volume.
V-5-1-5160
VxVM vxplex ERROR V-5-1-5160 Plex plex not associated to a snapshot
volume.
Description: An attempt was made to snap back a plex that is not from a snapshot volume.
Action: Specify a plex from a snapshot volume.
V-5-1-5161
VxVM vxplex ERROR V-5-1-5161 Plex plex not attached.
Description: An attempt was made to snap back a detached plex.
Action: Reattach the snapshot plex to the snapshot volume.