Chapter 6, Error Messages
Understanding Messages
59
V-5-0-216
VxVM vxio WARNING V-5-0-216 mod_install returned errno
◆ Description: A call made to the operating system mod_install function to load the
vxio driver failed.
◆ Action: Check for additional console messages that may explain why the load failed.
Also check the console messages log file for any additional messages that were logged
but not displayed on the console.
V-5-0-237
VxVM vxio WARNING V-5-0-237 object subdisk detached from RAID-5 volume
at column column offset offset
◆ Description: A subdisk was detached from a RAID-5 volume because of the failure of a
disk or an uncorrectable error occurring on that disk.
◆ Action: Check for other console error messages indicating the cause of the failure.
Replace a failed disk as soon as possible.
V-5-0-243
VxVM vxio WARNING V-5-0-243 Overlapping mirror plex detached from
volume volume
◆ Description: An error has occurred on the last complete plex in a mirrored volume.
Any sparse mirrors that map the failing region are detached so that they cannot be
accessed to satisfy that failed region inconsistently.
◆ Action: The message indicates that some data in the failing region may no longer be
stored redundantly.
V-5-0-244
VxVM vxdmp NOTICE V-5-0-244 Path failure on major/minor
◆ Description: A path under the control of the DMP driver failed. The device major and
minor numbers of the failed device is supplied in the message.
◆ Action: None.