Veritas Volume Manager 4.1 Troubleshooting Guide (HP-UX 11i v3, February 2007)
Understanding Messages
56 VERITAS Volume Manager Troubleshooting Guide
V-5-0-145
VxVM vxio WARNING V-5-0-145 DRL volume volume is detached
◆ Description: A Dirty Region Logging volume became detached because a DRL log
entry could not be written. If this is due to a media failure, other errors may have been
logged to the console.
◆ Action: The volume containing the DRL log continues in operation. If the system fails
before the DRL has been repaired, a full recovery of the volume’s contents may be
necessary and will be performed automatically when the system is restarted. To
recover from this error, use the vxassist addlog command to add a new DRL log
to the volume.
V-5-0-146
VxVM vxdmp NOTICE V-5-0-146 enabled controller controller_name connected
to disk array disk_array_serial_number
◆ Description: All paths through the controller connected to the disk array are enabled.
This usually happens if a controller is enabled after maintenance.
◆ Action: None.
V-5-0-147
VxVM vxdmp NOTICE V-5-0-147 enabled dmpnode dmpnode_device_number
◆ Description: A DMP node has been marked enabled in the DMP database. This
happens when at least one path controlled by the DMP node has been enabled.
◆ Action: None.
V-5-0-148
VxVM vxdmp NOTICE V-5-0-148 enabled path path_device_number belonging to
dmpnode dmpnode_device_number
◆ Description: A path has been marked enabled in the DMP database. This path is
controlled by the DMP node indicated by the specified device number. This happens
if a previously disabled path has been repaired, the user has reconfigured the DMP
database using the vxdctl(1M) command, or the DMP database has been
reconfigured automatically.
◆ Action: None.