Veritas Volume Manager 4.1 Troubleshooting Guide (HP-UX 11i v3, February 2007)
Understanding Messages
54 VERITAS Volume Manager Troubleshooting Guide
V-5-0-35
VxVM vxdmp NOTICE V-5-0-35 Attempt to disable controller controller_name
failed. Rootdisk has just one enabled path.
◆ Description: An attempt is being made to disable the one remaining active path to the
root disk controller.
◆ Action: The path cannot be disabled.
V-5-0-55
VxVM vxio WARNING V-5-0-55 Cannot find device number for boot_path
◆ Description: The boot path retrieved from the system PROMs cannot be converted to a
valid device number.
◆ Action: Check your PROM settings for the correct boot string.
V-5-0-106
VxVM vxio WARNING V-5-0-106 detaching RAID-5 volume
◆ Description: Either a double-failure condition in the RAID-5 volume has been detected
in the kernel or some other fatal error is preventing further use of the array.
◆ Action: If two or more disks have been lost due to a controller or power failure, use the
vxrecover utility to recover them once they have been re-attached to the system.
Check for other console error messages that may provide additional information
about the failure.
V-5-0-108
VxVM vxio WARNING V-5-0-108 Device major, minor: Received spurious close
◆ Description: A close was received for an object that was not open. This can only
happen if the operating system is not correctly tracking opens and closes.
◆ Action: No action is necessary; the system will continue.