Veritas Volume Manager 4.1 Troubleshooting Guide (HP-UX 11i v3, February 2007)

Chapter 1, Recovery from Hardware Failure
Recovery from Failure of a DCO Volume
19
Recovery from Failure of a DCO Volume
Note The FastResync feature is not supported by VxVM 4.1 on the HP-UX 11i v3
platform.
Note The procedures in this section depend on the DCO version number. See the
VERITAS Volume Manager Administrators Guide for information about DCO
versioning.
Persistent FastResync uses a data change object (DCO) volume to perform tracking of
changed regions in a volume. If an error occurs while reading or writing a DCO volume, it
is detached and the badlog flag is set on the DCO. All further writes to the volume are
not tracked by the DCO.
The following sample output from the vxprint command shows a complete volume
with a detached DCO volume (the TUTIL0 and PUTIL0 fields are omitted for clarity):
TY NAME ASSOC KSTATE LENGTH PLOFFS STATE ...
dg mydg mydg - - - -
dm mydg01 c4t50d0 - 35521408 - -
dm mydg02 c4t51d0 - 35521408 - -
dm mydg03 c4t52d0 - 35521408 - FAILING
dm mydg04 c4t53d0 - 35521408 - FAILING
dm mydg05 c4t54d0 - 35521408 - -
v SNAP-vol1 fsgen ENABLED 204800 - ACTIVE
pl vol1-03 SNAP-vol1 ENABLED 204800 - ACTIVE
sd mydg05-01 vol1-03 ENABLED 204800 0 -
dc SNAP-vol1_dcoSNAP-vol1 - - - -
v SNAP-vol1_dclgen ENABLED 144 - ACTIVE
pl vol1_dcl-03 SNAP-vol1_dclENABLED 144 - ACTIVE
sd mydg05-02 vol1_dcl-03 ENABLED 144 0 -
sp vol1_snp SNAP-vol1 - - - -
v vol1 fsgen ENABLED 204800 - ACTIVE
pl vol1-01 vol1 ENABLED 204800 - ACTIVE
sd mydg01-01 vol1-01 ENABLED 204800 0 -
pl vol1-02 vol1 ENABLED 204800 - ACTIVE
sd mydg02-01 vol1-01 ENABLED 204800 0 -
dc vol1_dco vol1 - - - BADLOG
v vol1_dcl gen DETACHED 144 - DETACH
pl vol1_dcl-01 vol1_dcl ENABLED 144 - ACTIVE
sd mydg03-01 vol1_dcl-01 ENABLED 144 0 -
pl vol1_dcl-02 vol1_dcl DETACHED 144 - IOFAIL
sd mydg04-01 vol1_dcl-02 ENABLED 144 0 RELOCATE
sp SNAP-vol1_snp vol1 - - - -