VERITAS Volume Manager 3.5 Troubleshooting Guide (September 2004)
Error Messages
vxdmp Notice Messages
Chapter 3
82
• Action: Check the underlying hardware if you want to recover the desired path.
NOTE vxvm:vxdmp:NOTICE:enabled controller controller_name connected to disk array
disk_array_serial_number
• Description: All paths through the controller connected to the disk array are enabled.
This usually happens if a controller is enabled after maintenance.
• Action: None.
vxvm:vxdmp:NOTICE:enabled dmpnode dmpnode_device_number
• Description: A DMP node has been marked enabled in the DMP database. This
happens when at least one path controlled by the DMP node has been enabled.
• Action: None.
vxvm:vxdmp:NOTICE:enabled path path_device_number belonging to dmpnode
dmpnode_device_number
• Description: A path has been marked enabled in the DMP database. This path is
controlled by the DMP node indicated by the specified device number. This happens
if a previously disabled path has been repaired, the user has reconfigured the DMP
database using the vxdctl(1M) command, or the DMP database has been
reconfigured automatically.
• Action: None.
vxvm:vxdmp:NOTICE: Path failure on major/minor
• Description: A path under the control of the DMP driver failed. The device major and
minor numbers of the failed device is supplied in the message.
• Action: None.
vxvm:vxdmp:NOTICE:removed disk array disk_array_serial_number
• Description: A disk array has been disconnected from the host, or some hardware
failure has resulted in the disk array becoming inaccessible to the host.
• Action: Replace disk array hardware if this has failed.