vxconfigd Notice Messages
A notice message from the configuration daemon, vxconfigd, indicates that VxVM has
taken some action that you may wish to monitor. Action should be taken to correct any
associated hardware problem as soon as possible.
vxvm:vxconfigd: NOTICE: Detached disk disk
• Description: The named disk appears to have become unusable and was detached
from its disk group. Additional messages may appear to indicate other records
detached as a result of the disk detach.
• Action: If hot-relocation is enabled, 3.5 objects affected by the disk failure are taken
care of automatically. Mail is sent to root indicating what actions were taken by
VxVM and what further actions the administrator should take.
vxvm:vxconfigd: NOTICE: Detached log for volume volume
• Description: The DRL or RAID-5 log for the named volume was detached as a result
of a disk failure, or as a result of the administrator removing a disk with vxdg -k
rmdisk. A failing disk is indicated by a “Detached disk” message.
• Action: If the log is mirrored, hot-relocation tries to relocate the failed log
automatically. Use either vxplex dis or vxsd dis to remove the failing logs. Then, use
vxassist addlog (see the vxassist(1M) manual page) to add a new log to the volume.
vxvm:vxconfigd: NOTICE: Detached plex plex in volume volume
• Description: The specified plex was disabled as a result of a disk failure, or as a
result of the administrator removing a disk with vxdg -k rmdisk. A failing disk is
indicated by a “Detached disk” message.
• Action: If hot-relocation is enabled, 3.5 objects affected by the disk failure are taken
care of automatically. Mail is sent to root indicating what actions were taken by
VxVM and what further actions the administrator should take.
vxvm:vxconfigd: NOTICE: Detached subdisk subdisk in volume volume
• Description: The specified subdisk was disabled as a result of a disk failure, or as a
result of the administrator removing a disk with vxdg -k rmdisk. A failing disk is
indicated by a “Detached disk” message.
• Action: If hot-relocation is enabled, 3.5 objects affected by the disk failure are taken
care of automatically. Mail is sent to root indicating what actions were taken by
VxVM and what further actions the administrator should take.
vxvm:vxconfigd: NOTICE: Detached volume volume
• Description: The specified volume was detached as a result of a disk failure, or as a
result of the administrator removing a disk with vxdg -k rmdisk. A failing disk is
indicated by a “Detached disk” message. Unless the disk error is transient and can
be fixed with a reboot, the contents of the volume should be considered lost.
• Action: Contact Customer Support.
vxvm:vxconfigd: NOTICE: Offlining config copy number on disk disk: