VERITAS Volume Manager 3.5 Troubleshooting Guide (August 2002)

Chapter 3, Error Messages
vxdmpadm Error Messages
71
vxvm:vxdmp:NOTICE: Path failure on major/minor
Description: A path under the control of the DMP driver failed. The device major and
minor numbers of the failed device is supplied in the message.
Action: None.
vxvm:vxdmp:NOTICE:removed disk array disk_array_serial_number
Description: A disk array has been disconnected from the host, or some hardware
failure has resulted in the disk array becoming inaccessible to the host.
Action: Replace disk array hardware if this has failed.
vxdmpadm Error Messages
An error message from the Dynamic Multipathing (DMP) administration utility,
vxdmpadm, indicates a problem with the requested DMP operation.
vxvm:vxdmpadm: ERROR: Attempt to disable controller failed. One (or
more) devices can be accessed only through this controller. Use the -f
option if you still want to disable this controller.
Description: Disabling the controller could lead to some devices becoming
inaccessible.
Action: To disable the only path connected to a disk, use the -f option.
vxvm:vxdmpadm:ERROR:Attempt to enable a controller that is not
available
Description: This message is returned by the vxdmpadm utility when an attempt is
made to enable a controller that is not working or is not physically present.
Action: Check hardware and see if the controller is present and whether I/O can be
performed through it.
vxvm:vxdmpadm: ERROR:The VxVM restore daemon is already running. You
can stop and restart the restore daemon with desired arguments for
changing any of its parameters.
Description: The vxdmpadm start restore command has been executed while the
restore daemon is already running.
Action: Stop the restore daemon and restart it with the required set of parameters.