VERITAS Volume Manager 3.5 Troubleshooting Guide (August 2002)
Chapter 3, Error Messages
vxdmp Notice Messages
69
vxvm: vxdg: ERROR: vxdg listmove sourcedg targetdg failed
vxvm:vxdg: ERROR: diskname : Disk not moving, but subdisks on it are
◆ Description: Some volumes have subdisks that are not on the disks implied by the
supplied list of objects.
◆ Action: Use the -o expand option to vxdg listmove to produce a self-contained list
of objects.
vxdmp Notice Messages
A notice message from the Dynamic Multipathing (DMP) driver, vxdmp, indicates that it
has taken some action that you may wish to monitor. Action should be taken to correct
any associated hardware problem as soon as possible.
vxvm:vxdmp:NOTICE:added disk array disk_array_serial_number
◆ Description: A new disk array has been added to the host.
◆ Action: None.
vxvm:vxdmp:NOTICE:Attempt to disable controller controller_name failed.
Rootdisk has just one enabled path.
◆ Description: An attempt is being made to disable the one remaining active path to the
root disk controller.
◆ Action: The path cannot be disabled.
vxvm:vxdmp:NOTICE: Could not install sd driver
vxvm:vxdmp:NOTICE: Could not install ssd driver
vxvm:vxdmp:NOTICE: Could not load sd driver
vxvm:vxdmp:NOTICE: Could not load ssd driver
◆ Description: During initialization, the vxdmp driver failed to load or install the sd or
ssd driver.
◆ Action: None.
vxvm:vxdmp:NOTICE: Could not lock sd driver
vxvm:vxdmp:NOTICE: Could not lock ssd driver
◆ Description: The sd or ssd driver could not be locked during vxdmp driver
initialization to avoid unloading of the driver.
◆ Action: None.