VERITAS Volume Manager 3.5 Troubleshooting Guide (August 2002)
vxconfigd Notice Messages
64 VERITAS Volume Manager Troubleshooting Guide
◆ Action: If hot-relocation is enabled, VERITAS Volume Manager objects affected by the
disk failure are taken care of automatically. Mail is sent to root indicating what
actions were taken by VxVM and what further actions the administrator should take.
vxvm:vxconfigd: NOTICE: Detached log for volume volume
◆ Description: TheDRL or RAID-5 log for the namedvolume was detached as a resultof
a disk failure, or as a result of the administrator removing a disk with vxdg -k
rmdisk. A failing disk is indicated by a “Detached disk” message.
◆ Action: If the log is mirrored, hot-relocation tries to relocate the failed log
automatically. Use either vxplex dis or vxsd dis to remove the failing logs. Then,
use vxassist addlog (see the vxassist(1M) manual page)to add a new logto the
volume.
vxvm:vxconfigd: NOTICE: Detached plex plex in volume volume
◆ Description: The specified plex was disabled as a result of a disk failure, or as a result
of the administrator removing a disk with vxdg -k rmdisk. A failing disk is
indicated by a “Detached disk” message.
◆ Action: If hot-relocation is enabled, VERITAS Volume Manager objects affected by the
disk failure are taken care of automatically. Mail is sent to root indicating what
actions were taken by VxVM and what further actions the administrator should take.
vxvm:vxconfigd: NOTICE: Detached subdisk subdisk in volume volume
◆ Description: The specified subdisk was disabled as a result of a disk failure, or as a
result of the administrator removing a disk with vxdg -k rmdisk. A failing disk is
indicated by a “Detached disk” message.
◆ Action: If hot-relocation is enabled, VERITAS Volume Manager objects affected by the
disk failure are taken care of automatically. Mail is sent to root indicating what
actions were taken by VxVM and what further actions the administrator should take.
vxvm:vxconfigd: NOTICE: Detached volume volume
◆ Description: The specified volume was detached as a result of a disk failure, or as a
result of the administrator removing a disk with vxdg -k rmdisk. A failing disk is
indicated by a “Detached disk” message. Unless the disk error is transient and can be
fixed with a reboot, the contents of the volume should be considered lost.
◆ Action: Contact Customer Support.
vxvm:vxconfigd: NOTICE: Offlining config copy number on disk disk:
Reason: reason
◆ Description: AnI/O errorcaused the indicatedconfiguration copy to bedisabled. This
is a notice only, and does not normally imply serious problems, unless this is the last
active configuration copy in the disk group.