VERITAS Volume Manager 3.2 for HP-UX Release Notes

VERITAS Volume Manager 3.2 for HP-UX Release Notes
Compatibility Information and Installation Requirements
Chapter 132
EMC Symmetrix (DMP active/active)
High Availability Storage System (HASS) A3311A/12A (no DMP support)
HP SureStore Disk Array 12H (DMP active/active)
HP High Availability Fibre Channel Disk Array Model 30/FC (DMP active/passive)
HP High Availability SCSI Disk Array Model 20 (DMP active/passive)
NOTE In order to configure DMP with active/active peripherals, you must have
B9116AA, the VERITAS Volume Manager 3.2 for HP-UX, installed. Without
B9116AA, you cannot set up DMP and can only configure a single path from the
host to an active/active peripheral. Active/active peripherals cannot be
configured as active/passive.
DMP and HP Surestore Disk Arrays xp256, xp512, and xp48
HP Surestore Disk Arrays xp256, xp512, and xp48 are supported with Dynamic Multipathing
(DMP) in active/active mode. If VxVM encounters devices with identical VxVM Disk IDs, the
VxVM software will give a preference to selecting the P-Vol as opposed to the S-Vol to resolve
the conflict. This disk selection policy will work only for the following microcode revisions:
xp256 microcode revisions 5244 and above
xp512 microcode revisions 1122 and above
xp48 microcode revisions 1122 and above
DMP and EMC Symmetrix Disk Array Support
The Dynamic Multipathing feature (DMP) of the Volume Manager works with the EMC
Symmetrix disk array only if the disk array is configured in the Common Serial Number
Mode. This is because only the Common Serial Number Mode configuration provides unique
device identification on different paths for DMP to configure its database. Without this mode,
DMP cannot provide the multipathing functionality. DMP cannot access EMC Symmetrix
disks as individual disks with a single path it found by scanning the device information tree
in the kernel.
For the DMP functionality to work with the EMC Symmetrix disk array, the following
conditions must be met:
It is necessary that the EMC Symmetrix users program their disk arrays in the Common
Serial Number Mode before installing the Volume Manager package.
The minimum level of microcode on the EMC Symmetrix should be:
5265 or 5266 for Sym-4 on models 3330, 3430, and 3700