VERITAS Volume Manager 3.1 Reference Guide
Table Of Contents

Chapter 2 97
Error Messages
Kernel Error Messages
vxvm:vxio:NOTICE: read error on object
subdisk
of mirror
plex in
volume
volume
(start
offset
, length
length
) corrected.
• Description
A read error occurred, which caused a read of an alternate mirror and
a writeback to the failing region. This writeback was successful and
the data was corrected on disk.
• Action
No action is required. The problem was corrected automatically. The
administrator may, however, note the failure as a reference because if
the same region fails again or frequently, the error could indicate a
more insidious failure and the disk should be reformatted at the next
reasonable opportunity.
String
on volume device in disk group
vxvm:vxio:NOTICE:
string
on volume device
_ #
(
device_name
) in disk group
group_name
• Description
An application requested message. The application running on top of
the Volume Manager has requested the output of this message.
• Action
Refer to documentation for the appropriate application for more
information.
Kernel Warning Messages
The following are warning messages associated with the kernel.
Received spurious close
vxvm:vxio:WARNING: Device
major
,
minor
: Received spurious
close
• Description
This message happens if a close was received for an object that was
previously not opened. This will only happen if the operating system
is not correctly tracking opens and closes.