VERITAS Volume Manager 3.1 Reference Guide
Table Of Contents

96 Chapter2
Error Messages
Kernel Error Messages
Kernel Error Messages
The following sections cover the kernel level error messages.
Kernel Notice Messages
The following are notice messages associated with the kernel.
Can’t open disk in group
vxvm:vxio:NOTICE: Can’t open disk
disk
in group
disk_group
.
If it is removable media (like a floppy), it may not be
mounted
or ready. Otherwise, there may be problems with the
drive.
Kernel error code
number
• Description
The named disk cannot be accessed in the named disk group.
• Action
Ensure that the disk exists, is powered on, and is visible to the
system.
Can’t close disk in group
vxvm:vxio:NOTICE: Can’t close disk
disk
in group
disk_group
. If it
is removable media (like a floppy), it may have been
removed.
Otherwise, there may be problems with the drive. Kernel
error
code
public_region_error
/
private_region_error
• Description
This is unlikely to happen; closes cannot fail.
• Action
None.
Read error on object of mirror in volume corrected