VERITAS Volume Manager 3.1 Reference Guide
Table Of Contents

84 Chapter2
Error Messages
DMP Error Messages
array
disk array serial number
• Description
All paths that go through the specified controller connected to the
specified disk array, have been put into enabled state. This happens
when the user chooses to enable a particular controller.
• Action
None.
Removed disk array
vxvm:vxdmp:NOTICE:removed disk array
disk array serial
number
• Description
The specified disk array has been disconnected from the host or some
hardware failure has resulted in the disk array becoming inaccessible
to the host.
• Action
None.
Added disk array
vxvm:vxdmp:NOTICE:added disk array
disk array serial
number
• Description
The new disk array has been added to the host.
• Action
None.
Attempt to enable a controller that is not available
vxvm:vxdmpadm:ERROR:
Attempt to enable a controller that is not available
• Description
This message is returned by the vxdmpadm utility when an attempt to
enable a controller that is not working or physically present is made.
To enable a controller, it should be visible to the OS and I/Os should
be possible through it.