VERITAS Volume Manager 3.1 Administrator's Guide
Introduction to Volume Manager
Virtual Object Data Organization (Volume Layouts)
Chapter 140
this example, subdisks disk02-02 and disk02-03 are available for other
disk management tasks.
Figure 1-10, Example of Spanning, shows data spread over two subdisks
in a spanned plex.
Figure 1-10 Example of Spanning
CAUTION Spanning a plex across multiple disks increases the chance that a disk
failure results in failure of the assigned volume. Use mirroring or
RAID-5 (both described later) to reduce the risk that a single disk failure
results in a volume failure.
Striping (RAID-0)
Striping
(RAID-0) maps data so that the data is interleaved among two
or more physical disks. A striped plex contains two or more subdisks,
spread out over two or more physical disks. Data is allocated alternately
and evenly to the subdisks of a striped plex.
The subdisks are grouped into “columns,” with each physical disk limited
disk02-01
B = Block of Data
VM Disks
Physical disks
disk01-01
disk02-02
disk02-03
Data in
disk01-01
Data in
disk02-0
Plex
disk01
disk01-01
devname
devname
disk02
disk02-01
disk02-02
disk02-03
B2
B1
B3
B4
B5
B6
B7
B8