Veritas Storage Foundation 5.1 SP1 for Oracle RAC Administrator"s Guide (5900-1512, April 2011)

Refer also to the vxfentsthdw(1M) manual page.
About general guidelines for using vxfentsthdw utility
Review the following guidelines to use the vxfentsthdw utility:
The utility requires two systems connected to the shared storage.
Caution: The tests overwrite and destroy data on the disks, unless you use the
-r option.
The two nodes must have ssh (default) or rsh communication. If you use rsh,
launch the vxfentsthdw utility with the -n option.
After completing the testing process, you can remove permissions for
communication and restore public network connections.
To ensure both systems are connected to the same disk during the testing, you
can use the vxfenadm -i diskpath command to verify a disks serial number.
See Verifying that the nodes see the same disk on page 118.
For disk arrays with many disks, use the -m option to sample a few disks before
creating a disk group and using the -g option to test them all.
The utility indicates a disk can be used for I/O fencing with a message
resembling:
The disk /dev/vx/rdmp/c1t1d0 is ready to be configured for
I/O Fencing on node galaxy
If the utility does not show a message stating a disk is ready, verification has
failed.
If the disk you intend to test has existing SCSI-3 registration keys, the test
issues a warning before proceeding.
About the vxfentsthdw command options
Table 2-4 describes the methods that the utility provides to test storage devices.
Table 2-4
vxfentsthdw options
When to useDescriptionvxfentsthdw option
Use when rsh is used for
communication.
Utility uses rsh for
communication.
-n
107Administering SF Oracle RAC and its components
Administering I/O fencing