Veritas Storage Foundation 5.1 SP1 Cluster File System Installation Guide (5900-1510, April 2011)

To check and change SCSI initiator IDs
1
For systems with PA architecture, turn on the power of the first system.
During the boot process, the system delays for ten seconds, giving you the
opportunity to stop the boot process and enter the boot menu:
To discontinue, press any key within 10 seconds.
Press any key. The boot process discontinues.
Boot terminated.
2
When you see the boot Main Menu, display the Information Menu by entering:
Main Menu: enter command or menu > in
3
From the Information Menu, enter "io" at the prompt for I/O interface
information:
Information Menu: Enter command > io
The output shows information about the I/O interfaces and resembles:
Path Bus Slot Vendor Device
Description (dec) # # Id Id
----------- ---- --- ----- ------ ------
.
.
SCSI bus cntlr 0/3/0/0 24 10 0x1000 0xf
.
4
Return to the Main Menu:
Information Menu: Enter command > main
5
Go the Service Menu:
Main Menu: enter command or menu > ser
6
Display the host bus adapters SCSI ID:
Service Menu: enter command or menu > scsi
The output displays information about the SCSI devices:
Before you install
Setting up shared storage
36