Veritas Storage Foundation 5.1 SP1 Cluster File System Installation Guide (5900-1510, April 2011)

15
Start Storage Foundation High Availability 5.1 SP1 for HP-UX 11i v3 using
the following command:
# ./ installsfha -start
16
Check if the VEA service was restarted:
# /opt/VRTS/bin/vxsvcctrl status
17
If the VEA service is not running, restart it:
# /opt/VRTS/bin/vxsvcctrl start
18
Disk groups that were created using VxVM 5.0 can be imported after upgrading
to VxVM 5.1.100. However, we recommend upgrading the VxVM disk groups
to the latest version.
Upgrading from SFHA or SFORAHA 4.1, 4.1 MP1, 4.1 MP2, 5.0.
5.0 MP1, or 5.0 MP2 on HP-UX 11i v2 to SFHA 5.1 SP1 on HP-UX
11i v3
If your systems are already running Storage Foundation High Availability 4.1, 4.1
MP1, 4.1 MP2, 5.0. 5.0 MP1, or 5.0 MP2 on HP-UX 11i v2, you must upgrade the
operating system to HP-UX 11i v3. Then upgrade Storage Foundation High
Availability to Storage Foundation High Availability 5.1 SP1.
Prepare to upgrade Veritas products
See Preparing to upgrade the Veritas software on page 194.
Prepare to upgrade SFHA or SFORAHA on HP-UX 11iv2 to HP-UX 11iv3
See Preparing to upgrade SFHA or SFORAHA on HP-UX 11i v2 to HP-UX 11i
v3 on page 231.
Upgrade HP-UX
See Upgrading the HP-UX operating system on page 237.
Upgrade SFHA
See Upgrading SFHA or SFORA HA on HP-UX 11i v2 to 5.1 SP1 on page 233.
Preparing to upgrade SFHA or SFORAHA on HP-UX 11i v2 to HP-UX 11i v3
Perform the following steps before you upgrade SFHA or SFORAHA on HP-UX
11i v2 to SFHA on HP-UX 11i v3.
231Performing a phased upgrade
Upgrading Storage Foundation Cluster File System and High Availability software from a release prior to 5.1 SP1