Veritas Storage Foundation 5.1 SP1 Cluster File System Installation Guide (5900-1510, April 2011)

Verifying I/O fencing configuration
Verify from the vxfenadm output that the SCSI-3 disk policy reflects the
configuration in the /etc/vxfenmode file.
To verify I/O fencing configuration
1
On one of the nodes, type:
# vxfenadm -d
Output similar to the following appears if the SCSI3 disk policy is dmp:
I/O Fencing Cluster Information:
================================
Fencing Protocol Version: 201
Fencing Mode: SCSI3
Fencing SCSI3 Disk Policy: dmp
Cluster Members:
* 0 (galaxy)
1 (nebula)
RFSM State Information:
node 0 in state 8 (running)
node 1 in state 8 (running)
2
Verify that the disk-based I/O fencing is using the specified disks.
# vxfenconfig -l
Setting up server-based I/O fencing using installsfcfs
If Storage Foundation Cluster File System cluster is configured to run in secure
mode, then verify that the configuration is correct before you configure CP
server-based I/O fencing.
See Configuring server-based I/O fencing using the installsfcfs on page 159.
Configuring server-based I/O fencing using the installsfcfs
You can configure server-based I/O fencing for the Storage Foundation Cluster
File System cluster using the installsfcfs.
159Configuring SFCFS for data integrity
Setting up server-based I/O fencing using installsfcfs