Veritas Storage Foundation 5.1 SP1 Cluster File System Administrator"s Guide (5900-1738, April 2011)

To replace coordination points for an online cluster
1
Ensure that the SFCFS cluster nodes and users have been added to the new
CP server(s). Run the following commands:
# cpsadm -s cpserver -a list_nodes
# cpsadm -s cpserver -a list_users
If the SFCFS cluster nodes are not present here, prepare the new CP server(s)
for use by the SFCFS cluster.
See the Veritas Storage Foundation Cluster File System Installation Guide
for instructions.
2
Ensure that fencing is running on the cluster using the old set of coordination
points and in customized mode.
For example, enter the following command:
# vxfenadm -d
The command returns:
I/O Fencing Cluster Information:
================================
Fencing Protocol Version: <version>
Fencing Mode: Customized
Cluster Members:
* 0 (galaxy)
1 (nebula)
RFSM State Information:
node 0 in state 8 (running)
node 1 in state 8 (running)
3
Back up the /etc/vxfenmode file on each of the client cluster nodes.
Administering Storage Foundation Cluster File System and its components
Administering I/O Fencing
102