Veritas Storage Foundation 5.1 SP1 Cluster File System Administrator"s Guide (5900-1738, April 2011)
# export CPS_USERNAME=_HA_VCS_test-system@HA_SERVICES@test-system.symantec.com
# export CPS_DOMAINTYPE=vx
Once a pre-existing network partition is detected using the above commands, all
spurious keys on the coordinator disks or CP server must be removed by the
administrator.
To troubleshoot server-based I/O fencing configuration in mixed mode
1
Review the current I/O fencing configuration by accessing and viewing the
information in the vxfenmode file.
Enter the following command on one of the SFCFS cluster nodes:
# cat /etc/vxfenmode
vxfen_mode=customized
vxfen_mechanism=cps
scsi3_disk_policy=dmp
security=0
cps1=[10.140.94.101]:14250
vxfendg=vxfencoorddg
2
Review the I/O fencing cluster information.
Enter the vxfenadm -d command on one of the cluster nodes:
# vxfenadm -d
I/O Fencing Cluster Information:
================================
Fencing Protocol Version: 201
Fencing Mode: Customized
Fencing Mechanism: cps
Cluster Members:
* 0 (galaxy)
1 (nebula)
RFSM State Information:
node 0 in state 8 (running)
node 1 in state 8 (running)
191Troubleshooting SFCFS
Troubleshooting I/O fencing