Veritas™ File System 5.0.1 Administrator's Guide

vol1
/dev/vx/dsk/fsvol/ /fsvol_may_23 vxfs ckpt=may_23 0 0
vol1:may_23
To mount a Storage Checkpoint of a cluster file system, you must also use the
-o cluster option:
# mount -F vxfs -o cluster,ckpt=may_23 \
/dev/vx/dsk/fsvol/vol1:may_23 /fsvol_may_23
You can only mount a Storage Checkpoint cluster-wide if the file system that
the Storage Checkpoint belongs to is also mounted cluster-wide. Similarly,
you can only mount a Storage Checkpoint locally if the file system that the
Storage Checkpoint belongs to is mounted locally.
You can unmount Storage Checkpoints using the umount command.
# umount /fsvol_may_23
# umount /dev/vx/dsk/fsvol/vol1:may_23
Note: You do not need to run the fsck utility on Storage Checkpoint pseudo devices
because pseudo devices are part of the actual file system.
Converting a data Storage Checkpoint to a nodata Storage Checkpoint
A nodata Storage Checkpoint does not contain actual file data. Instead, this type
of Storage Checkpoint contains a collection of markers indicating the location of
all the changed blocks since the Storage Checkpoint was created.
See Types of Storage Checkpoints on page 88.
You can use either the synchronous or asynchronous method to convert a data
Storage Checkpoint to a nodata Storage Checkpoint; the asynchronous method
is the default method. In a synchronous conversion, fsckptadm waits for all files
to undergo the conversion process to nodata status before completing the
operation. In an asynchronous conversion, fsckptadm returns immediately and
marks the Storage Checkpoint as a nodata Storage Checkpoint even though the
Storage Checkpoint's data blocks are not immediately returned to the pool of free
blocks in the file system. The Storage Checkpoint deallocates all of its file data
blocks in the background and eventually returns them to the pool of free blocks
in the file system.
If all of the older Storage Checkpoints in a file system are nodata Storage
Checkpoints, use the synchronous method to convert a data Storage Checkpoint
to a nodata Storage Checkpoint. If an older data Storage Checkpoint exists in the
Storage Checkpoints
Storage Checkpoint administration
94