Veritas File System 4.1 Administrator's Guide (HP-UX 11i v3, February 2007)

Kernel Messages
Kernel Messages
Appendix B204
033 WARNING: msgcnt x: mesg 033: V-2-33: vx_check_badblock - mount_point file
system had an I/O error, setting VX_FULLFSCK
Description
When the disk driver encounters an I/O error, it sets a flag in the super-block
structure. If the flag is set, the kernel will set the VX_FULLFSCK flag as a
precautionary measure. Since no other error has set the VX_FULLFSCK flag, the
failure probably occurred on a data block.
•Action
Unmount the file system and use fsck to run a full structural check. Check the
console log for I/O errors. If the problem is a disk failure, replace the disk before
the file system is mounted for write access.
034 WARNING: msgcnt x: mesg 034: V-2-34: vx_resetlog - mount_point file system
can’t reset log
Description
The kernel encountered an error while resetting the log ID on the file system. This
happens only if the super-block update or log write encountered a device failure. The
file system is disabled to preserve its integrity.
•Action
Unmount the file system and use fsck to run a full structural check. Check the
console log for I/O errors. If the problem is a disk failure, replace the disk before
the file system is mounted for write access.
035 WARNING: msgcnt x: mesg 035: V-2-35: vx_inactive - mount_point file system
inactive of locked inode inumber
Description
VOP_INACTIVE was called for an inode while the inode was being used. This
should never happen, but if it does, the file system is disabled.
•Action
Unmount the file system and use fsck to run a full structural check. Report as a bug
to your customer support organization.
Table B-1 (Continued)
Message
Number
Message and Definition