Veritas File System 4.1 Administrator's Guide (HP-UX 11i v3, February 2007)

Kernel Messages
Kernel Messages
Appendix B 193
015 WARNING: msgcnt x: mesg 015: V-2-15: vx_ibadinactive - mount_point file system
can’t mark inode inumber bad
msgcnt x: mesg 015: V-2-15: vx_ilisterr - mount_point file system can’t mark inode
inumber bad
Description
An attempt to mark an inode bad on disk, and the super-block update to set the
VX_FULLFSCK flag, failed. This indicates that a catastrophic disk error may have
occurred since both an inode list block and the super-block had I/O failures. The file
system is disabled to preserve file system integrity.
•Action
Unmount the file system and use fsck to run a full structural check. Check the
console log for I/O errors. If the disk failed, replace it before remounting the file
system.
016 WARNING: msgcnt x: mesg 016: V-2-16: vx_ilisterr - mount_point file system error
reading inode inumber
Description
An I/O error occurred while reading the inode list. The VX_FULLFSCK flag is set.
•Action
Check the console log for I/O errors. If the problem was caused by a disk failure,
replace the disk before the file system is mounted for write access. Unmount the file
system and use fsck to run a full structural check.
Table B-1 (Continued)
Message
Number
Message and Definition