Migrating X.25 over ACC to X.25 over PSI
11
Step 5: Configure all the ports to be used for X.25 over PSI adapter using SAM or SMH. This
creates the X.25 configuration file and the X.25 device for each X.25 interface on the PSI adapter.
For more information on configuring X.25 using SAM or SMH, see HP X.25/9000 User’s guide
available at:
http://docs.hp.com/en/netcom.html#X.25
Note: - Apart from the X.25 configuration file, there is no separate configuration file required for
the X.25 subsystem configuration, as was required to bring up the ACC subsystem incase of
X.25/ACC along with the X.25 configuration file.
Step 6: Verify the X.25 link to check if it is up and running using the x25ifstate command.
For more details on X.25 commands and how to manage X.25/PSI, see the X.25 User guide
available at:
http://docs.hp.com/en/netcom.html#X.25
Configuration file for an X.25 interface over ACC
Following is the generic configuration file for an X.25 interface over ACC:
#@(#)NACC x25init.sample $Rev: /main/3 $"
#
x.121 35011
x.121_packetaddr 35011
device zx25m0p0
name x25_interface_name
#
# Level 2 Parameters
#
t1 3000
t3 60000
framesize 149
n2 20
l2window 7
#
# Level 3 Parameters
#
networktype DTE_88
#
# Circuit Table Definition
#
# LCI TYPE HOW MANY
lci 1 svc 255
#
# Flow Control, Throughput Class, Fast Select and Reverse Charge Settings