Installing and Administering FTAM/9000
42 Chapter 2
Configuring HP FTAM/9000
Additional Configuration Parameters
ae_max_active_assoc This parameter sets the number of connections
an FTAM application is allowed to have
established at any one time. This parameter is
important for FTAM applications that use low
level context sensitive functions and maintain
multiple connections at any one time.
FORMAT decimal number
UNIT connections/associations
RANGE 1 - 50
DEFAULT 20
OSICONF yes
DYNAMIC yes
SCREEN View/Modify FTAM Initiator
FIELD Maximum Number of
Associations/Invocation
ae_objid This object ID may optionally be sent by an application
or service during connection establishment, and may be
used for security or authentication purposes by non-HP
equipment. If the other equipment does not require this
object ID, no object ID should be configured. Globally
unique object IDs are assigned by CCITT and/or ISO; a
private organization can assign its own.
FORMAT ASCII string
UNIT NA
RANGE Elements of the object ID are separated by
periods. For example, 2.5.4.29