HP Fabric Clustering System HP-UX Administrator's Guide, March 2008
local-portnum : 2
vendor-id : 00:05:ad
subnet-prefix : fe:80:00:00:00:00:00:00
node-guid : 00:05:ad:00:00:00:13:da
base-version : 1
class-version : 1
type : switch
num-ports : 9
port-guid : 00:05:ad:00:00:00:13:da
partition-cap : 1
device-id : 0
revision : 0
local-portnum : 1
vendor-id : 00:05:ad…
The following example displays a node configuration in summary form.
HP-IB# show ib sm node subnet-prefix fe:80:00:00:00:00:00:00 node-guid 00:05:ad:00:00:00:13:80 summary
============================================================================
Subnet Manager Node Summary
============================================================================
subnet-prefix node-guid node-type vendor-id
----------------------------------------------------------------------------
fe:80:00:00:00:00:00:00 00:05:ad:00:00:00:13:80 channel adapter 00:05:ad
HP-IB#
The following example displays a node configuration in summary form.
HP-IB# show ib sm node subnet-prefix fe:80:00:00:00:00:00:00 node-guid 00:05:ad:00:00:00:13:80 summary
============================================================================
Subnet Manager Node Summary
============================================================================
subnet-prefix node-guid node-type vendor-id
----------------------------------------------------------------------------
fe:80:00:00:00:00:00:00 00:05:ad:00:00:00:13:80 channel adapter 00:05:ad
HP-IB#
Defaults: This command has no defaults.
Related Commands: “ib sm subnet-prefix” (page 182)
show ib sm partition
Synopsis: The show ib sm partition command displays partitions managed by Subnet
Managers on the device.
Syntax: show ib sm partition
Command Modes: User-execute and privileged-execute modes.
Privilege Level: InfiniBand read-only user.
Usage Guidelines: In the output, 7f:ff refers to the default Partition, which cannot be altered.
Members of Partitions are identified by their Node GUID and port-number, as displayed below.
A single Partition can have members that are both full-membership, as well as members that
have limited membership.
Examples: The following example displays the configuration of all the nodes on all the subnets
on the InfiniBand fabric.
HP-IB# show ib sm partition
===============================================================================
Partitions Managed By The Subnet Managers
===============================================================================
subnet-prefix : fe:80:00:00:00:00:00:00
p_key : 7f:ff
partition-members :
node-guid : 00:05:ad:00:00:00:02:40
port-number : 0
member-type : full-member
node-guid : 00:05:ad:00:00:00:02:42
port-number : 0
member-type : full-member
node-guid : 00:05:ad:00:00:00:02:42
port-number : 0
member-type : full-member
Defaults: This command has no defaults.
Related Commands: “ib sm subnet-prefix” (page 182)
146 Switch Command Line Interface