HP Fabric Clustering System HP-UX Administrator's Guide, March 2008
Table B-14 show ib sm node subnet-prefix Command Syntax Descriptions (continued)
DescriptionSyntax
Use with the all keyword.
node guid
Displays a Subnet Manager node summary.
summary
Command Modes: User-execute and privileged-execute modes.
Privilege Level: InfiniBand read-only user.
Usage Guidelines: Use this command to display the configuration of all the nodes on a subnet,
or to display the configuration of an individual node. The output may also be displayed in
summary form. The summary comprises the subnet-manager prefix, the node GUID and type,
and vendor identification.
The fields in the show ib sm node output are described in the table below.
Table B-15 show ib sm node subnet-prefix Command Field Descriptions
DescriptionField
64-bit value that identifies the InfiniBand subnet to which this node belongs.subnet-prefix
GUID of this node.node-guid
Description of device, is one has been configured.description
Supported base management datagram (MAD) version. Indicates that this channel adapter, switch,
or router supports up to and including this version. See section 13.4.2, Management Datagram
Format, in “InfiniBand® Architecture, Vol. 1, Release 1.0”, for more information.
base-version
Supported MAD class format version. Indicates that this channel adapter, switch, or router supports
up to, and including, this version. This column is displayed in the “Advanced” view only.
class-version
Type of node being managed. The value is channel adapter, switch, router, or error. error indicates
an unknown type.
type
Number of physical ports on this node.num-ports
GUID of this port. A port within a node can return the node GUID as its PortGUID if the port is an
integral part of the node and is not field-replaceable (i.e., not swappable). This column is displayed
in the “Advanced” view only.
port-guid
Number of entries in the partition table for channel adapter, router, and the switch management
port. The value is the same for all ports on the node. This is set to at least 1 for all nodes including
switches. This column is displayed in the “Advanced” view only.
partition-cap
Manufacturer-assigned device identification. This column is displayed in the “Advanced” view
only.
device-id
Manufacturer-assigned device revision. This column is displayed in the “Advanced” view only.revision
The link port number this subnet management packet (SMP) came in on. The value is the same for
all ports on the node. This column is displayed in the “Advanced” view only.
local-portnum
Device vendor ID. The value is the same for all ports on the node.vendor-id
Examples: The following example displays the configuration of all the nodes on all the subnets
on the InfiniBand fabric.
HP-IB# show ib sm node subnet-prefix all
============================================================================
Subnet Management Nodes
============================================================================
subnet-prefix : fe:80:00:00:00:00:00:00
node-guid : 00:05:ad:00:00:00:11:97
base-version : 1
class-version : 1
type : channel adapter
num-ports : 2
port-guid : 00:05:ad:00:00:00:11:99
partition-cap : 64
device-id : 0
revision : 0
Show Commands 145