HP Instant Capacity support for HP Integrity Superdome 2 with Dynamic Cores - Release Notes (762795-001, March 2014)
This problem can be solved by using TiCAP to boot up the partition. Use the command icapmodify
–T on to turn on the TiCAP pre-authorization flag on OA. See the TiCAP pre-authorization usage
matrix, in the HP Integrity Superdome 2 with dynamic cores chapter in HP Instant Capacity 10.x
User Guide.
Command timeout
When a command timeout occurs while executing icapmodify -a or -d,
nl
there can be a mismatch between Intended Active and Actual Active values. You must execute
icapmodify -s to correct this mismatch.
Expiration time for TiCAP in warning message in OA syslog is not correct
If the warning period message appears in the OA syslog, the complex is in warning period. If the
expiration time for TiCAP is not logged correctly in this message, refer to the icapstatus command
output for TiCAP expiration time.
NOTE: If firmware version 3.6.48 or later is installed on HP Integrity Superdome 2, the expiration
date appears both in the OA syslog and the email message, but the actual expiration time doesn't
appear.
Low-level WBEM errors (HP-UX)
Occasionally, on a busy system, especially one with many partitions, you may see errors, such as
the following:
ERROR: The following low-level WBEM error occurred:
Empty HTTP response message.
or:
ERROR: The following low-level WBEM error occurred:
Locking or unlocking the target failed.
These errors result from contention for system resources from the various partitions in the complex.
If you see these messages, retry the Instant Capacity operation.
Restarting OA updates old audit snapshot information
Active OA continues to have the old hardware resource information even after the memory and
processors are replaced or repaired. In this case, restarting OA is necessary to update the audit
snapshot information.
Creating a codeword for upgrading Superdome 2 from 16-socket to 32-socket
You need to execute icapstatus -s either from OA or HP-UX on the 16-socket system prior to
the hardware upgrade and create an upgrade codeword on the iCAP portal http://www.hp.com/
go/icap/portal. By clicking Upgrade Codeword, you can launch the Create Superdome 2
codeword for 16-socket to 32-socket Upgrade wizard.
You need to apply the upgrade codeword after the physical upgrade task.
GiCAP Known problems (HP-UX)
Resolving errors during addition of a standby GM
While adding a standby GM there is a possibility of certificate exchange failure
nl
for the Superdome 2 members. This can be resolved by re-adding the member to the GM.
12 Instant Capacity support for HP Integrity Superdome 2 with dynamic cores release notes