HP Instant Capacity release notes for Version 10.x (March 2011)

At this point the member can be removed using the icapmanage -r command.
Software Requirements
Every HP-UX and OpenVMS partition in an Instant Capacity system is required to have the Instant
Capacity software installed and the icapd daemon running (on HP-UX systems), or the ICAP_SERVER
process running (on OpenVMS systems). You must maintain the Instant Capacity software until all
program requirements are fulfilled and until the system is no longer considered an Instant Capacity
system. If you are using GiCAP, all systems must be running Instant Capacity version 9.x (or later).
NOTE: For necessary HP-UX updates, install the latest Operating Environments Update Release
(OEUR) or Application Release (AR) update, if possible. This ensures that you install all required
products and versions. Instant Capacity does not work correctly with HP-UX releases prior to
December 2004.
Your Instant Capacity system is ordered and shipped with all of the following required software
and dependent products, except for the vPars software and the GiCAP requirement on the CIM
Server configuration property. If your system’s operating system is reinstalled or installed with
Ignite-UX, ensure that the following software requirements are satisfied.
HP-UX 11i v1 Requirements and Dependent Products
The following software is required for Instant Capacity version 9.x (or later) on HP-UX 11i v1:
HP-UX 11i v1
iCAP software bundle B9073BA (version 9.x or later) On the 11i v1 Applications Software
media, or download the most recent version from the HP Software Depot at:
http://www.hp.com/go/softwaredepot
The kernel configuration must include the diag2 module.
WBEM B8465BA bundle (version A.02.05 or higher)
nParProvider bundle (version B.12.01.06.02 or higher, available from the OE media)
If you have a virtual partitioned environment, the Virtual Partitions (vPars) software (bundle
T1335AC) must be version A.03.05 or higher. vPars is available separately and is not included
with the OE.
(GiCAP only) The CIM Server configuration property sslClientVerificationMode must be set to
a value of optional” on all GiCAP Group Managers and on all OS instances of all member
systems. (The CIM Server may need to be restarted if the property was not previously set to
this value.) For details on setting sslClientVerificationMode, see “Upgrading Version 8.x Groups
to Version 9.x or Later (page 30). Note that communication between the managers and
members of groups is established using SSL certificates that are supplied by the GiCAP software.
Required Patches for HP-UX 11i v1
The following patches are required for Instant Capacity version 9.x (or later) on HP-UX 11i v1:
PHKL_22987: S700_800 11.11 pstat() patch (Use only if your system runs
MeasureWare software)
PHKL_23154: S700_800 11.11 dflush() patch
PHKL_25218: S700_800 11.11 PDC Call retry, PDC_SCSI_PARMS, iCOD hang
fix
PHKL_26232: S700_800 11.11 Psets Enablement patch, FSS iCOD patch
PHKL_30197: S700_800 11.11 Psets & vPar, Reboot hangs, serial number
PHCO_24396: S700_800 11.11 /etc/default/tz patch
Software Requirements 27