HP-UX 11i v3 March 2014 Release Notes

HP-UX WBEM IOTree Indication Provider: Not supported on HPVM guest OS. Includes
defect fixes. See HP-UX WBEM IOTree Indication Provider Release Notes at http://
hp.com/go/hpux-networking-docs.
HP-UX WBEM nPartition Provider: Delivers defect fixes. See the product release notes at
http://hp.com/go/hpux-networking-docs.
HP-UX WBEM RAIDSA Provider: Not supported on HPVM guest OS. Indication provider
supports System GUID and Network address properties. Includes defect fixes. See HP-UX
WBEM RAIDSA Provider Release Notes at http://hp.com/go/hpux-networking-docs.
HP-UX WBEM SAS Provider: Not supported on HPVM guest OS. Indication provider
supports System GUID and Network address properties. Includes defect fixes. As
OnlineDiag is not supported on newer platforms, the dm_sas_adapter monitor used
by SAS Indication provider on newer servers will be replaced by
HPUXSASNativeIndicationProviderModule. See HP-UX WBEM SAS Provider
Release Notes at http://hp.com/go/hpux-networking-docs.
HP-UX WBEM SCSI Provider: Not supported on HPVM guest OS. Includes defect fixes.
See HP-UX WBEM SCSI Provider Release Notes at http://hp.com/go/
hpux-networking-docs.
HP-UX WBEM vPartition Provider: Delivers defect fixes. See the product release notes at
http://hp.com/go/hpux-networking-docs.
WBEMP-LAN Provider: Includes defect fix. See HP-UX WBEM LAN Provider Release Notes
at http://hp.com/go/hpux-networking-docs.
September 2010 Release Notes, Disk and file management
HP-UX Disks and File Systems (fsweb): disklist command is now fixed to display a disk
as “Used” if the volume group configured on it is deactivated. A few internally found issues
are fixed.
Logical Volume Manager (LVM): Provides the automatic increase of pre-allocated extents when
the threshold value is reached for space-efficient snapshots; enables you to change the size
and mirror count of an original logical volume on a snapshot tree; optimizes resynchronization
I/Os of snapshot mirrors by resynchronizing only the unshared units of the extents. See HP-UX
Logical Volume Manager and MirrorDisk/UX Release Notes at http://hp.com/go/
hpux-core-docs.
ONCplus: Includes parallel mount feature for performance improvement and defect fixes. See
ONCplus B.11.31.09.01 Release Notes at http://hp.com/go/hpux-networking-docs.
Symantec Products (VxFS and VxVM): All new HP Integrity systems based on the Intel® Itanium®
9300 Processor are supported with VxFS and VxVM version 5.0 (and later) on HP-UX 11i v3.
These systems are not supported with VxFS and VxVM version 4.1.
September 2010 Release Notes, Internet and networking
BIND: Version 9.3.2 contains fixes for security vulnerabilities. See BIND 9.3.2 Release Notes
at http://hp.com/go/hpux-networking-docs.
HP-UX Auto Port Aggregation (APA): HP APA supports the use of fixed MAC addresses. See
HP Auto Port Aggregation (APA) Release Notes at http://hp.com/go/hpux-networking-docs.
HP-UX Directory Server (HPDS): HPDS Administration Server updated to add support for HP-UX
Apache-based Web Server version 2.2. Includes a defect fix. See HP-UX Directory Server
8.1.02 Release Notes at http://www.hp.com/go/hpux-security-docs. (Click HP-UX Directory
Server.)
What is new in the HP-UX 11i v3 September 2010 release 59