HP-UX 11i v3 Installation and Update Guide, March 2014
Messages you can ignore
Table 15 describes harmless messages currently known to appear while installing or updating to
HP-UX 11i v3.
Table 15 Messages you can ignore
Message/actionWhen/where seen
When the BOE is installed from the DC-OE, HA-OE, or VSE-OE media, an erroneous
listing for HA Monitors (bundle B5736DA) might be displayed. Even though HA
When the BOE is installed from the
DC-OE, HA-OE, or VSE-OE media,
Monitors appears to be part of the BOE, the product is only available on the DC-OE,an erroneous listing for HA
Monitors might appear HA-OE, and VSE-OE. While the bundle wrapper for B5736DA is included in the
install, the complete product, itself, is not installed.
This behavior only occurs when a BOE is installed from DC-OE, HA-OE, or VSE-OE
media. It does not occur if you install the BOE from BOE media.
What to do
Do not attempt to install or uninstall the B5736DA bundle. You can safely ignore
its display.
ERROR: File "/var/adm/sw/products/PHCO_41129/pfiles/configure"
does not exist
After upgrading from older HP-UX
11i v3 OEUR (which has
ERROR: Script is defined, but does not exist
VxFS/VxVM 5.0 or VxFS/VxVM
5.0.1 installed) to HP-UX 11i v3
ERROR: File "/var/adm/sw/products/PHCO_42177/pfiles/configure"
March 2014 OEUR, you might see
does not exist
the following ERROR messages in
swagent.log:
ERROR: Script is defined, but does not exist
ERROR: File "/var/adm/sw/products/PHCO_42794/pfiles/configure"
does not exist
ERROR: Script is defined, but does not exist
ERROR: File "/var/adm/sw/products/PHCO_40771/pfiles/configure"
does not exist
ERROR: Script is defined, but does not exist
Description
As part of upgrade, VxFS/VxVM 5.0 or VxFS/VxVM 5.0.1 patches are
automatically selected for install. But, VxFS/VxVM 5.1 SP1 products that are
shipped with HP-UX 11i v3 March 2014 OEUR remove older versions of
VxFS/VxVM products. Hence, the error messages occur.
What to do
You can safely ignore these messages as there is no functional impact. You can
use the following update-ux command to avoid the errors:
# update-ux -s source_location
!PHCO_41129!PHCO_42177!PHCO_42794!PHCO_40771
ERROR: [40269] Symlink "/opt/VRTS/bin/fsppmk" should have
value
After upgrading from older HP-UX
11i v3 OEUR (which has
"../../../usr/lbin/fs/vxfs5.0/fsppmk" but the actual value
VxFS/VxVM 5.0) to HP-UX 11i v3
is
March 2014 OEUR, you might see
"/opt/VRTSfspro/bin/fsppmk"
the following ERROR messages in
swagent.log:
ERROR: [40269] Symlink "/opt/VRTS/bin/fstag" should have
value
"../../../usr/lbin/fs/vxfs5.0/fstag" but the actual value
is
"/opt/VRTSfspro/bin/fstag"
ERROR: [40269] Symlink "/opt/VRTS/bin/mkdstfs" should have
value
"../../../usr/lbin/fs/vxfs5.0/mkdstfs" but the actual value
is
"/opt/VRTSfspro/bin/mkdstfs"
[140113] Fileset "VRTSvxfs.VXFS-RUN,l=/,r=5.1.100.000" had
file errors
Description
74 Harmless messages and known problems