HP-UX 11i v3 Installation and Update Guide, March 2010
Table A-2 Known install and update problems (continued)
Description/actionProblem
After an HP-UX 11i v3 install/update, the swverify command may report that
one or more of the following ONCplus.NFS manpage files is missing:
/usr/share/man/man1m.Z/portmap.1m
/usr/share/man/man1m.Z/umount_nfs.1
/usr/share/man/ja_JP.eucJP/man1m.Z/umount_nfs.1m
/usr/share/man/ja_JP.SJIS/man1m.Z/umount_nfs.1m
The hard links to the affected manpages were incorrectly removed by the
install/update process.
What to do
As superuser, recreate the missing links by executing the following commands,
as needed:
# cd /usr/share/man/man1m.Z
# ln rpcbind.1m portmap.1m
# ln mount_nfs.1m umount_nfs.1m
# cd /usr/share/man/ja_JP.eucJP/man1m.Z
# ln mount_nfs.1m umount_nfs.1m
# cd /usr/share/man/ja_JP.eucJP
# ln mount_nfs.1m umount_nfs.1m
NFS*MAN filesets produce
swverify errors during
install/update or removal
If you are on an HP-UX 11i v1 system and perform swcopy, swlist, or
swverify on a depot containing HP-UX 11i v2 or HP-UX 11i v3 software, you
may encounter the following warning message:
WARNING: Ignoring duplicate information for the keyword
“dynamic_module” at line.
What to do
For swlist or swverify on HP–UX 11i v1, you can safely ignore this message.
For swcopy on HP–UX 11i v1, install patch PHCO_28848 (or a superseding patch)
on the HP–UX 11i v1 system, then re-run the swcopy command with "-x
reinstall=true".
Warning message when
performing swcopy, swlist, or
swverify
Known install and update problems 85