HP-UX 11i v3 Installation and Update Guide, March 2010
Table A-1 Messages you can ignore (continued)
Message/actionWhen/where seen
* [140112] Checking files for fileset
"HPOvLcore.HPOVXPL,l=/,r=6.20.%343".
WARNING: [40257] Directory "/var/opt/OV/conf/xpl" should
have mode "555" but the actual mode is "2755".
WARNING: [40259] Directory "/var/opt/OV/conf/xpl" should
have owner,uid "bin,2" but the actual owner,uid
is "root,0".
WARNING: [40257] Directory "/var/opt/OV/conf/xpl/trc"
should have mode "555" but the actual mode is
2775".
WARNING: [40259] Directory "/var/opt/OV/conf/xpl/trc"
should have owner,uid "bin,2" but the actual
owner,uid is "root,0".
WARNING: [140114] Fileset
"HPOvLcore.HPOVXPL,l=/,r=6.20.%343" had file
warnings.
What to do
You can safely ignore these messages. You will see these messages when updating
to GlancePlus Pak v5.00 from HP-UX 11i v2 or HP-UX 11i v3. You will also see
the messages if you have the older version of the product on your system and
swinstall the newer version. To prevent these messages, install patch
PACPTHP_00002 from the ITRC (http://itrc.hp.com). For more information, see
QCCR1A98520 at http://support.openview.hp.com/selfsolve/documents.
While upgrading HP GlancePlus
Pak to version 5.00 from the
Application Software media, the
following swverify errors are
logged in swagent.log.ver:
WARNING: mod_uninstall: Attempt to uninstall
hvsd module:
Module is not installed
WARNING: mod_uninstall: Attempt to uninstall
hssn module:
Module is not installed
What to do
You can safely ignore these messages. They do not indicate any problem with
the installation.
During the installation or update
of Integrity VM along with the
HostAvioStor and/or the
HostAvioLan products, the
following warning messages
may be seen in /var/adm/
syslog/syslog.log:
DIAGNOSTIC SYSTEM WARNING:
The diagnostic logging facility has started
receiving excessive errors from the I/O subsystem.
I/O error entries will be lost until the cause of
the excessive I/O logging is corrected.
What to do
You can safely ignore this warning for the USB DVD unit. Install or update from
OE media will succeed.
During cold-install or update to
the HP-UX 11i v3 March 2009 (or
later) OE media, you may see the
following diagnostic warning
when using a USB DVD unit:
*[902] Running "preinstall" script for fileset
"VRTSob.VEAS-FILESET".
- [902] kill: 1944: The specified process
does not exist.
*[367] Running "preinstall" script for fileset
"VRTSob.VEAS-FILESET
succeeded with 1 warning.
*[1394] Installing fileset
"VRTSob.VEAS-FILESET,r=3.3.837.0"
(841 of 1062).
What to do
You can safely ignore this message. Installation is not affected. VRTSob will start
without any problem once the update is complete.
While updating from a previous
OEUR to the HP-UX 11i v3
September 2008 OEUR and
beyond, the following messages
regarding VRTSob may be logged
onto the console:
Messages you can ignore 77