HP-UX 11i v3 Installation and Update Guide, September 2011

Known install and update problems
Table 15 (page 75) describes problems currently known to occur while installing and/or updating
to HP-UX 11i v3.
Table 15 Known install and update problems
Description/actionProblem
Upon using update-ux(1M) to update a system that contains a version of HP-UX
WBEM Direct Attached Storage Provider (DASProvider) prior to vB.11.31.1106
Upon update,
WBEMP-Storage.STORAGE-PROV-RUN
filesets might not be configured (HP-UX 11i v3 March 2011 OEUR or earlier), the
WBEMP-Storage.STORAGE-PROV-RUN fileset might not be configured. Trying
to configure the fileset using swconfig(1M) might also fail. The following might be
seen in the /var/adm/sw/swagent.log file:
* Running "configure" script for fileset
"WBEMP-Storage.STORAGE-PROV-RUN".
NOTE: Disabling old Disk Native Provider.
ERROR: PGC00617: Disabling the provider module...
PGS00414: Connection timed out.
NOTE: Removing old Disk Native Provider.
NOTE: PGC00614: Deleting the provider module...
PGC00607: The provider is deleted successfully.
NOTE: Creating the Disk log database
NOTE: Disk log database setup completed.
NOTE: Registering Storage WBEM Indication
Provider schema
NOTE: Registering Storage WBEM Instance Provider schema
NOTE: Registering Storage WBEM Record Log Provider
NOTE: Registering Storage Native Control Provider
NOTE: Registering the Storage WBEM Native Provider.
ERROR: The "configure" script for
"WBEMP-Storage.STORAGE-PROV-RUN" failed
(exit code "1"). The script location was
"/var/adm/sw/products/WBEMP-Storage.2/
STORAGE-PROV-RUN/configure".
What to do
Uninstall the currently running DASProvider, where the problem is seen. Then
install either DASProvider vB.11.31.1106 (available on the web) or
vB.11.31.1109.05.01 (delivered in the HP-UX 11i v3 September 2011 OEUR).
Upon upgrade of the September 2008 and March 2009 version of
WBEMP-IOTreeIP, plus the PHSS_40180 patch, to the March 2010, September
Warning messages generated
upon upgrading WBEMP-IOTreeIP
2010, or September 2011 version of WBEMP-IOTreeIP, you might see the
following messages during swverify of WBEMP-IOTreeIP:
WARNING: Directory "/var/opt/iotreeip" should have mode
"555"
but the actual mode is "755".
WARNING: Directory "/var/opt/iotreeip" should have owner,uid
"bin,2"
but the actual owner,uid is "root,0".
WARNING: Directory "/var/opt/iotreeip" should have group,gid
"bin,2"
but the actual group,gid is "other,1".
WARNING: Directory "/var/opt/iotreeip/config" should have
mode "555"
but the actual mode is "755".
WARNING: Fileset
"WBEMP-IOTreeIP.IOTREEIP-LIB,l=/,r=B.11.31.1009"
had file warnings.
What to do
Remove the older version of WBEMP-IOTreeIP and reinstall the September 2011
version of WBEMP-IOTreeIP afresh.
Known install and update problems 75