Using Dual Port 100Base-TX and Dual Port Wide Ultra2 SCSI

Chapter 4 37
Troubleshooting SCSI
Troubleshooting
0x04 0x04 logical unit not ready, format in progress
0x05 0x00 logical unit does not respond to selection
0x06 0x00 reference position found
0x07 0x00 multiple peripheral devices selected
0x08 0x00 logical unit communication failure
0x08 0x01 logical unit communication time-out
0x08 0x02 logical unit communication parity error
0x09 0x00 track following error
0x09 0x01 tracking servo failure
0x09 0x02 focus servo failure
0x09 0x03 spindle servo failure
0x0a 0x00 error log overflow
0x0c 0x00 write error
0x0c 0x01 write error recovered with auto reallocation
0x0c 0x02 write error - auto reallocation failed
0x10 0x00 id crc or ecc error
0x11 0x00 unrecovered read error
0x11 0x01 read retries exhausted
0x11 0x02 error too long to correct
0x11 0x03 multiple read errors
0x11 0x04 unrecovered read error - auto reallocate failed
0x11 0x05 l-ec uncorrectable error
0x11 0x06 circ unrecovered error
0x11 0x07 data resynchronization error
0x11 0x08 incomplete block read
0x11 0x09 no gap found
0x11 0x0a miscorrected error
0x11 0x0b unrecovered read error - recommend reassignment
0x11 0x0c unrecovered read error - recommend rewrite the data
SCSI Additional Sense and Qualifier Codes (Continued)
Additional
Sense Code
Qualifier
Code
Description