HP Fibre Channel Mass Storage Adapters Support Guide, February 2007
Chapter 3
Troubleshooting and Maintenance
HP Support Tools Manager
43
-----------------------------------------------------------
Severity Level: Error
1Bolt Value: 88417
Error 17: The Fibre Channel Driver received a LINK DOWN interrupt.
Additional Information:
Frame Manager Status Register = 0x1
Received AL_PA Register = 0x2
Loss of Signal Counter = 3
Bad Received Character Count = 4
Loss of Synchronization Count = 5
Link Failure Count = 6
Received EOF Count = 9
Generated EOF Count = 8
Bad CRC Count = 9
Protocol Error Count = 10
Possible Causes/Recommended Actions:
It is possible for link down errors to occur under normal operation.
No action is required. The system will recover.
• Diagnose Tool
The Diagnose Tool runs a loopback test on a Fibre Channel adapter. This test is destructive and must only
be run by qualified personnel or on instruction from an HP Support Representative.
NOTE STM also includes a Firmware Update tool. This tool cannot be used to update the firmware on
Fibre Channel adapters.
The rom_fw_update option within the fcmsutil command can be used to update the firmware
on A6826A, A9782A, A9784A, AB465A, AB378A, AB378B, AB379A, AB379B, and AD300A
adapters.