Interface Card OL* Support Guide

Chapter 5
Comparing and Combining OL* Methods
Mixing OL* Methods
88
Mixing OL* Methods
These tools allow the completion of the operation using a different method than what was used to initiate the
process, but some there are some cautions to doing this, and some subsequent actions will be slightly
different.
1. If you accidentally press the Attention Button before installing the card, be sure to power OFF the slot
before installing the card using the same method you used initially.
Table 5-1 Consequences of Mixing OL* Methods
Start
Replace
Process
Complete
Replace
Process
Comments and Actions to Bring the Slot Power ON
pdweb olrad You are in the middle of a sequence of pdweb screens. Select [Cancel] or [Defer]
upon returning to pdweb, however they both return to the main screen of
pdweb without issuing the olrad -R command. If you return to pdweb and hit
[OK], the olrad -R command will be re-run. This will gracefully fail since the
slot power is already ON.
pdweb
Attention
Button
1
olrad pdweb
Launch pdweb and use the [Bring Card Online..] button to complete the
operation. The [Add Card...] or [Replace Card...] actions usually used to complete
the operation (with the new card selected) will be grayed out.
Attention
Button
pdweb
olrad Attention
Button
1
Works with no additional actions needed.
Attention
Button
olrad