Interface Card OL* Support Guide

Chapter 2
pdweb - Peripheral Device Tool Web Interface
Replacing a Card Online
56
Step 2. Click the button appropriate to your course of action.
If you chose [Power Off] or [Force Power Off], you are advanced to Step 2 of the Replace Card
process and these events are initiated:
the amber attention LED is set to flashing
the target slot is powered off if necessary
the target slot green power LED is set to steady OFF
If any other button is chosen, control returns to the OLRAD Cards tab and
the state of the target slot is unchanged.
CAUTION Do not push the Attention Button on the slot, if it exists, as this causes the slot to be
powered on and an attempt to bring the card online prematurely is executed by the
system.
IMPORTANT Only replace a card in a slot when the Power LED is OFF.
At the system, locate the target slot then confirm that the green power LED is off and that the
amber attention LED is flashing before proceeding. If this is not the case, refer to “Messages from
pdweb Actions” on page 90.
System Critical
Warning
[Done] Terminate the card replacement as
it would be detrimental to the
system.
Error [Done] Terminate the card replacement as
a problem exists that should be
investigated using the information
provided in the CRA.
Table 2-5 pdweb Replace a Card CRA Results (Continued)
CRA Result
Available
Actions
Suggested Course of Action