HP-UX 11i Version 2 Installation and Update Guide, September 2004
Table Of Contents
- 1 Welcome to HP-UX 11i Version 2
- 2 System Requirements for Cold-Installing and Updating
- 3 Choosing an Installation Method
- Supported Cold-Install Paths to HP-UX 11i v2
- Supported Update Paths to HP-UX 11i v2
- Deciding Which Method to Use
- Time to Complete a Cold Install or Update
- When to Cold-Install
- When to Update
- Additional Cold-Install Considerations
- Additional Update Considerations
- Requirement for Updating from HP-UX 11i v1.6 (B.11.22)
- Requirement for Updating from Earlier Releases of HP-UX 11i v2 (B.11.23)
- HP Service Partition Is Not Created During Update (Itanium-based Systems Only)
- Update-UX Contains a Default-Installed Selection File
- Update-UX Creates Two Backup Configurations
- Security Considerations
- Standard HP-UX Bundle Considerations
- Online Diagnostics
- Offline Diagnostics
- The Next Step
- 4 Preparing to Install or Update to HP-UX 11i v2
- 5 Cold-Installing HP-UX 11i v2
- 6 Updating to HP-UX 11i v2
- 7 Installing HP Applications and Patches
- 8 Verifying System Install or Update
- A Data Collection Tables
- B Known Problems and Troubleshooting
- C Controlling Memory Utilization of VxFS 3.5 on HP-UX
- D Software Distribution Media
- HP-UX 11i v2 Core Software Bundles
- HP-UX 11i v2 Always-Installed Patch Bundles
- HP-UX 11i v2 Always-Installed Software Bundles
- HP-UX 11i v2 Always-Installed Network and Mass Storage Drivers
- HP-UX 11i v2 Default-Installed Software Bundles
- HP-UX 11i v2 Selectable Software Bundles
- HP-UX 11i v2 Selectable Network Drivers

Known Problems and Troubleshooting
Problems Reading HP-UX 11i v1 DVD Media
Appendix B 163
Problems Reading HP-UX 11i v1 DVD Media
The HP-UX 11i v1 DVD media contains large volumes of data that may
cause your DVD device to fail while reading the DVD media contents
during an update. This particularly affects you if you use Update-UX or
other Software Distributor (SD) tools. For example, you may encounter
similar error messages if you attempt to read DVD media with a large
volume of data from Update-UX:
ERROR: File "/dvd/catalog/SOE/SOE.2/INFO": No such file or
directory(2). Cannot copy it to file
"/var/tmp/BAAa04482/catalog/SOE/SOE.2/INFO".
ERROR: File "/var/tmp/BAAa04482/catalog/SOE/SOE.2/INFO" does
not exist.
ERROR: The catalog files for product "SOE,r=B.11.11" failed to
load. Check the above output for details.
ERROR: Cannot continue the Analysis Phase until the previous
errors are corrected.
To resolve this problem, do one of the following:
• For HP-UX 11.00 or 11.11, install the appropriate patches listed in
this section before you update to the latest version of HP-UX 11i v1
(recommended).
• For HP-UX 10.20, use the pfs_mount (1M) command to mount the
DVD.
To patch your system, use the following patches (patch descriptions are
in parentheses) for your current OS version:
NOTE The listed HP-UX 11i v1 patches are included in the December 2003 (and
later) version of the HP-UX 11i v1 install kernel. If you are planning to
cold-install HP-UX 11i v1 (December 2003 or later), you do not need to
install these patches.