HP-UX 11i v2 Read Before Installing or Updating, September 2006

What To Do
After cold-installing the HP-UX 11i v2 September 2006
release, check the swagent.log file. If the error messages
shown above are present, remove the System Fault
Management (SysFaultMgmt) product from your system
and reinstall it as a stand-alone component.
1. Log in as superuser.
2. To uninstall System Fault Management, enter the
following at the command prompt:
# /usr/sbin/swremove SysFaultMgmt
3. To install System Fault Management, enter the
following command at the HP-UX prompt:
# swinstall -x autoselect_dependencies=true -x
enforce_dependencies=true -s /tmp/cdrom
SysFaultMgmt
For more information on installation of the System
Fault Management product, see the System Fault
Management Administrator's Guide at:
http://docs.hp.com/en/diag.html