PCI FDDI Administrator's Guide

Troubleshooting PCI FDDI
Diagnostics
Chapter 382
Speed = 100000000
Station Address = 0x0060B0d69a3
Administration Status(value) = up (1)
Operation Status (value) = up (1)
Last Change = 1011981975
Inbound Octets = 22404656
Inbound Unicast Packets = 26
Inbound Non-Unicast Packets = 0
Inbound Errors = 0
...
lanscan
The lanscan command verifies that the link Hardware State is up. It
displays information about each LAN device that has software support
on the system. The Hdw State field shows the hardware state. If the
state is DOWN, the driver cannot communicate with the card and may
indicate:
The driver has detected operational problems. Use lanadmin to reset
the card.
The card may be bad. Check the LEDs.
/usr/sbin/lanscan
hpntch4 # /usr/sbin/lanscan
Hardware Station Crd Hdw Net-Interface NM MAC HP-DLPI DLPI
Path Address In# State NamePP ID Type Support Mjr#
0/0/0 0x0060B0D690A3 0 UP lan0 1 FDDI Yes 119
0/1/0 0x0060B0069099 1 UP lan1 2 FDDI Yes 119
linkloop(1M)
The linkloop(1M) command verifies LAN connectivity with link-level
loopback. It tests the connectivity of the local node and the remote node
specified by the hardware station address by sending a link-level TEST
packet and checking for the response.