NetWare 4.1/9000 Utilities Reference
3-39
Server Utilities
nwcm
spx_max_sockets=
number
Specify how many sockets SPX can use
simultaneously for listening for connect
requests from other end points.
You can set this parameter so that small
systems can efficiently use allocated memory
for optimal system performance.
Increase the value if applications are failing
because listening sockets cannot be opened.
Supported values: 5 to 1010
Default: 1010
Table 3-4 SAP Parameters
Parameter Use to
sap_dump_file=value Specify the name of the file that receives the
output when the SAP daemon dumps the
SAP tables.
The dump is initiated by sending the SAP
daemon a SIGPIPE and is generally used for
debug.
Values are any valid HP-UX filename
(created in the directory log_directory), a
valid path and filename, or /dev/null
(disables logging).
Maximum length: 127
Default: “sap.dump”
Table 3-3 IPX/SPX Parameters
Parameter Use to