NetWare 4.1/9000 Concepts

1-50
NetWare Glossary
E
In an Ethernet environment, stations communicate with each other by
sending data in frames along an Ethernet cabling system.
Different Ethernet standards use different frame formats. NetWare 4 uses the
IEEE 802.2 standard by default.
NetWare Services uses 802.2 as its default if no IPX networks are found. If
Networks are discovered, NWDISCOVER configures the frame type to
match.
The following figure illustrates the Ethernet 802.2 frame.
Figure 1-17 Ethernet 802.2 frame
Use a frame statement to configure stations for Ethernet standards other than
802.2. For servers and routers, add the frame statement to the nwconfig file.
For workstations, add the frame statement to the NET.CFG file.
In addition to 802.2, you can use one of the following frame types:
Ethernet 802.3. The default frame type used in NetWare 3.11 and earlier. This
frame type is also referred to as the raw frame. Don’t use this frame on a network
that uses protocols other than IPX. The following figure illustrates the Ethernet
802.3 raw frame.
Destination Source Length
DSAP SSAP
Data unit
1
2
Control
662
11
42-14961 or 2
All units in bytes
46-1500