Support Plus User Guide HP-UX 11i Version 1, December 2003

Support Plus User Guide HP-UX 11i v1
Problems Reading HP-UX 11i v1 DVD Media
Chapter 1 25
Problems Reading HP-UX 11i v1 DVD Media
The HP-UX 11i v1 DVD media contain large volumes of data that may
cause your DVD device to fail while reading the DVD media contents.
This particularly affects you if you use Update-UX or other Software
Distributor (SD) tools. For example, you may encounter similar error
messages if you attempt to read DVD media with a large volume of data
from Update-UX:
ERROR: File "/dvd/catalog/SOE/SOE.2/INFO": No such file or
directory(2). Cannot copy it to file
"/var/tmp/BAAa04482/catalog/SOE/SOE.2/INFO".
ERROR: File "/var/tmp/BAAa04482/catalog/SOE/SOE.2/INFO" does
not exist.
ERROR: The catalog files for product "SOE,r=B.11.11" failed to
load. Check the above output for details.
ERROR: Cannot continue the Analysis Phase until the previous
errors " are corrected.
To resolve this problem, do one of the following:
install the appropriate patches listed below before you update to the
latest version of HP-UX 11i v1 (recommended), or
•use the pfs_mount (1M) command to mount the DVD (see “Using
pfs_mount to Mount a DVD on page 27).
Patching Your System to Read DVD Media
To patch your system use the following patches for your current OS
version.
NOTE The following HP-UX 11i v1 patches are included in the December 2003
(and later) version of the HP-UX 11i v1 install kernel. If you are
planning to cold-install HP-UX 11i v1 (December 2003 or later), you do
not need to install these patches, nor do you need to use the
pfs_mount (1M) command to mount the DVD.