Software Distributor Administration Guide for HP-UX 11i
Command Options
Options Listed Alphabetically
Appendix A 443
• logdetail=false
Controls the amount of detail written to the log file. When set to true,
this option adds detailed task information, such as options specified,
progress statements, and additional summary information, to the log
file.
Table A-1 shows the possible combinations of loglevel and
logdetail options.
Applies to swconfig, swcopy, swinstall, swreg, swremove and
swverify.
Table A-2 loglevel and logdetail Combinations
Log Level Log Detail Information Included
loglevel=0 (not applicable) No information is written to the
log file
loglevel=1 logdetail=false Only key events are logged. This is
the default setting for both options.
loglevel=1 logdetail=true Event detail as above plus task
progress messages. (Setting
loglevel=1
is optional because 1
is the default value.)
loglevel=2 logdetail=false Event and file level messages only.
(Setting
logdetail=false
is
optional because false is the
default value.)
loglevel=2
a
logdetail=true All information is logged.
a. This combination duplicates the logfile behavior as HP-UX
10.x releases. Setting both the
loglevel=2
and
logdetail=true
options is required.