EMS Hardware Monitoring Shutdown Errors
You may see the following error messages upon shutdown of the
EMS Hardware Monitors:
KILLMON ERROR: could not find a dictionary file containing the
monitor name '/connectivity/events/multiplexors/FC_SCSI_mux'.
KILLMON ERROR: could not find a dictionary file containing the
monitor name '/system/events/orca_win'
What To Do
1. Stop the emslistener using the following command:
/sbin/init.d/rstemsListener stop
2. Comment out the following monitor details in the
/var/stm/config/tools/monitor/isee.sapcfg file:
##############################################
MONITOR: /connectivity/events/multiplexors/FC_SCSI_mux
Criteria Threshold: INFORMATION
Criteria Operator: >=
Target Type: TEXTLOG
Target TEXTLOG File: /var/opt/resmon/log/rst.log
Client Config File:
/var/stm/config/tools/monitor/rst_dm_fc_scsi_mux.clcfgMO
NITOR: /connectivity/events/multiplexors/FC_SCSI_mux
Criteria Threshold: INFORMATION
Criteria Operator: >=
Target Type: TCP