Managing Systems and Workgroups: A Guide for HP-UX System Administrators

Administering a System: Booting and Shutdown
Booting Systems
Chapter 5 509
Configuring Boot-Time System Tests from a Booted System
SpeedyBoot tests are configured with three setboot options:
-v Displays a status table of the SpeedyBoot test settings.
-t
testname
=
value
Change the value for the test
testname
in nonvolatile
memory to
value
for all following boots. The changes
are reflected in the Current and Next Boot columns
of the SpeedyBoot table.
testname
One of the following keywords, as
described in Table 5-2 on page 503:
all
SELFTESTS
early_cpu
late_cpu
FASTBOOT
full_memory
PDH
CEC
value
One of:
on
Enable the test.
off
Disable the test.
default
Reset the test to the system
default, which is shown in the
Defaults column of the
SpeedyBoot table.
NOTE The -t option (lowercase t) is supported only on HP
9000 Systems. To change SpeedyBoot settings for all
subsequent boots on an HP Integrity Server, use the
preboot environment, the EFI shell. See “Configuring
Boot-Time System Tests from the EFI Shell (HP
Integrity Servers Only)” on page 507 for details.