HP-UX HB v13.00 Ch-19 - PRM

HP-UX Handbook Rev 13.00 Page 6 (of 31)
Chapter 19 Process Resource Manager (PRM)
October 29, 2013
For all FSS PRM groups in the configuration
The CPUCAPON mode, enabled through the prmconfig -M option discussed below,
treats the FSS PRM group’s minimum allocation as its maximum allocation. When
CPUCAPON mode is enabled, CPU capping is in effect for all user-configured FSS PRM
groups on a system - regardless of CPU load. Each FSS PRM group takes its entire CPU
allocation. Thus, no group can obtain more CPU resources.
For PSET PRM groups, capping is a result of the number of cores assigned to the group.
Installation
Current PRM Version and Patches
Install the full PRM product, B3835DA, on systems where you want PRM to control resource
allocations.
HP PRM is included with HP-UX 11i v3 and can be purchased for use with HP-UX 11i v1 and
HP-UX 11i v2. A 90-day trial version can be downloaded from the HP Software Depot.
HP Process Resource Manager (PRM) Version C.03.05 supports:
HP-UX 11i v1 (B.11.11) operating system on HP 9000 servers
HP-UX 11i v 2 (B.11.23) operating system running on either HP 9000 servers or HP
Integrity servers
HP-UX 11i v3 (B.11.31) operating system running on either HP 9000 servers or HP
Integrity servers
HP Process Resource Manager (PRM) Version C.03.05.01 supports:
HP-UX 11i v 2 (B.11.23) operating system running on either HP 9000 servers or HP
Integrity servers
HP-UX 11i v3 (B.11.31) operating system running on either HP 9000 servers or HP
Integrity servers
The current versions are available on the application DVDs:
B3835DA C.03.05.01 HP Process Resource Manager
B3835DA C.03.05 HP Process Resource Manager
The PRM software includes 4 products:
PRM-Sw-Gui C.03.05.01 Process Resource Manager PRM-Sw-Gui product
PRM-Sw-Krn C.01.05 Process Resource Manager PRM-Sw-Krn product
PRM-Sw-Lib C.03.05.01 Process Resource Manager PRM-Sw-Lib product
PRM-Sw-Sim C.03.05.01 Process Resource Manager PRM-Sw-Sim product